SOLLICH 2159 PCG
Programmable Current Source, Galvanostat, Imax=4,5A

Stabilized current source – galvanostat.

High accuracy – setting resolution 0.1%.

Assembled in a case, easy to carry and transport.

Battery power Li-Ion 6400mAh.

TO QUOTE THE PRODUCT, CONTACT THE MANUFACTURER.

Documentation

and technical data

Description

1. Destiny

Programmable Current Source SOLLICH 2159 PCM is a precise DC power supply (galvanostat).

The device is designed to work in the field and in laboratory conditions as a regulated and switched source of direct current. In particular, the functions of the device have been adapted to the needs of calculating the resistance of the pipeline section in underground installations.

It is widely used in cathodic protection research, as a portable source of polarization current in tests and research testing the distribution of cathodic protection currents on underground metal structures.
2.Construction

The SOLLICH 2159 PCS is assembled in a carrying case, easy to carry and transport, in which the internal power source (batteries) is built in. The method of assembling the internal elements of the device guarantees the required resistance to shocks, which allows it to be used freely in the conditions of field measurements.

The main element of the device is a stabilized current source – a galvanostat, working with very high accuracy – setting resolution 0.1%.

The galvanostat is powered by internal Li-Ion batteries.

The output current of the galvanostat is programmed manually using the CURRENT multi-turn potentiometer. The current can take values in the entire current range, from 0.0 to I_max (I_max depends on the version of the device).

The device is equipped with a digital AMMETER meter that allows you to measure and read current current values. Additionally, an external test ammeter can be connected to the A-METER terminals to measure the polarization current at the OUTPUT output.

The device has POLARITY SWITCH and CURRENT INTERRUPTION switches that enable manual switching of the current polarity at the OUTPUT terminals, or its momentary switching off.

The device is equipped with a digital meter VOLTMETER that allows you to measure the voltage at the OUTPUT output terminals. The task of the voltmeter is to check whether the device works in the linear range of output voltages.
3. Equipment

The SOLLICH 2159 PCS device is standardly equipped with:

Suitcase with accessories – 1 pc.
A-METER terminal jumper – 1 pc.
Battery charger installed in the device – 1 pc.

Technical Data

< /table>

Additional products

offering additional options

Masz więcej pytań?

Zostaw email, odezwiemy się do Ciebie!

2159_front
You're viewing: SOLLICH 2159 PCG
Programmable Current Source, Galvanostat, Imax=4,5A

Add to the order
0

Your Cart

ParameterValue
Maximum output current Imax:           for the device version 3A4Vfor the device version 4.5A2.3V 3 A4.5 A
CURRENT bias current measurement accuracy0.2% +/- 2.5 mA
Resolution current measurement0.1 mA
Maximum output voltage OUTPUT – linear operating range: Umax for the device version 3A4VUmaxfor device version 4.5A2.3V 0 .. +4V V0 .. +2.3V
Output voltage measurement range OUTPUT0 .. 5 V< /td>
Output voltage measurement accuracy OUTPUT2% +/- 0, 1V
Input voltage measurement range INPUT 0 .. +100 mV
Output voltage measurement accuracy INPUT0.2% + /- 0.1 mV
Current polarity switching POSITIVE / NEGATIVE Manual
Internal battery capacity Li-Ion6400 mAh< /td>
Working time on built-in batteries, at ImaxMax. 3.5 hours
Dimensions (W x D x H):270x250x120mm
Weight:3.5 kg