SOLLICH 2103 SOK
Cathodic Protection Station for fuel tanks, Imax=4A

Cathodic Protection Station with low power consumption, dedicated to systems operating in a wide range of ambient temperatures.

Application for cathodic protection of:

  • different types of pipelines
  • steel constructions
  • tanks for liquid and gas fuels

Controlled by a microprocessor.

All modes and functions are available.

Power supply: 12 – 48 Vdc

RS 485 communication interface. Modbus RTU

PRICE DEPENDS ON PRODUCT CONFIGURATION.

SKU: 0-2-1-1 Categories: ,

Documentation

and technical data

Description

Cathodic Protection Station SOLLICH 2103 CATHODIC PROTECTION STATION is designed for cathodic protection of metal structures, built locally as well as in a large area, on its surface, in water, with good insulation in relation to the ground. In particular, these are all kinds of liquid and gaseous fuel tanks, pipelines and gas pipelines.

The Cathodic Protection Station works in a three-electrode system with a reference electrode or in a two-electrode system without this electrode. The -/K cathode and the Ku terminal are connected to the protected structure.

The OK station (Cathodic Protection) enables temporary switching off of the protection current.
The OK station enables the implementation of the described task in an automatic way by adjusting the operating parameters so as to force the set value of current or potential. The device has the ability to manually and remotely change the operating mode and parameters.

The Cathodic Protection Station measures the following parameters:

Ip – structure polarization current.
Uak – anode voltage – construction.
Eon – switching potential of the structure.
Eoff – the structure’s shutdown potential.
Uac_on – RMS value of AC interference signals occurring on the structure.
Uac_off – RMS value of AC interference signals occurring on the structure.
E(t) – Measurement of the structure potential time course. “Oscilloscope” mode.

The SOLLICH 2103 CPS station requires a DC voltage supply with parameters depending on the version
execution.

version: 24-1000 (Us = 12 … 28V; Ip_max = 1000 mA)
version: 24-2000 (Us = 12 … 28V; Ip_max = 2000 mA)
version: 24-4000 (Us = 12 … 28V; Ip_max = 4000 mA)
version: 48-1000 (Us = 24 … 52V; Ip_max = 1000 mA)
version: 48-2000 (Us = 24 … 52V; Ip_max = 2000 mA)

Features of the device

  1. Operation in
    • galvanostatic mode – forcing a constant protection current
    • potentiostatic mode – forcing a constant protection potential
  2. Diversity of functions allowing configuration for a wide range of applications
  3. Possibility of programmatic disconnection of the station
  4. Current and potential regulation
  5. Automatic measurements
  6. Built-in accurate and interference-resistant measurement systems
  7. Recording changes in the structure’s potential over time. “Oscilloscope” mode.
  8. Analog-digital implementation of regulation and control systems
  9. Alphanumeric LCD display visible in the dark
  10. Information about the current operating status, alarm signals
  11. Built-in external logical inputs enabling control of the station operation
  12. Built-in external logical outputs enabling control of the operation of other devices in the OK installation
  13. Registration of protection parameters and signal values ​​in non-volatile memory
  14. High energy efficiency
  15. Remote reading of operating parameters
  16. Communication socket with external devices – RS485
  17. Support for Modbus protocol
  18. Made in accordance with the EMC directive
  19. Wide operating temperature range
  20. Simple installation on a DIN rail
  21. Simple start-up, easy service

Technical Data

  1. TECHNICAL PARAMETERS
No.Electrical output parameters of the device:UnitMin valueMax valueNotes
1. Station power supply voltage  0V, UsV24 or 48Depending on the model
Minimum output current of the Station power supplyFor model: SOLLICH 2103 CPS / 24-1000A2 Power supplies meeting the condition:24V-45W,
For model: SOLLICH 2103 CPS / 24-2000A2.5 Power supplies meeting the condition:24V-60W,
For the model: SOLLICH 2103 CPS / 24-4000A5 Power supplies meeting the condition:24V-120W,
For model: SOLLICH 2103 CPS / 48-1000A2 Power supplies meeting the condition:48V-100W,
For model: SOLLICH 2103 CPS /48-2000A2.5 Power supplies meeting condition:48V-120W,
2.Protection output current – ​​Ip nominal current – ​​programmable valuemA2.51000Model 24-1000
Current measurement inaccuracy Ip%+mA2% +/- 2.5 mA
Protection output current – Ipnominal current – ​​programmable valuemA52000Model 24-2000
Current measurement inaccuracy Ip%+mA2% +/- 5 mA
Protection output current – ​​Ipnominal current – ​​programmable valuemA104000Model 24-4000
Ip current measurement inaccuracy%+mA2% +/- 10 mA
Protection output current – ​​Ip nominal current – ​​programmable valuemA2.51000Model 48-1000
Current measurement inaccuracy Ip%+mA2% +/- 2.5 mA
Protection output current – ​​Ip nominal current – ​​programmable valuemA52000Model 48-2000
Current measurement inaccuracy Ip%+mA2% +/- 5 mA
3.Potential programming rangeEp,at the terminals Eo-KpV0-5 
4.Potential measurement range Ep,onEo-Kp terminals V0+/-7V 
5.Potential measurement inaccuracy EpmV+%+/- 2mV +/- 0.5% 
6.RMS measurement range of AC interference at terminals Eo-KpVrms07 Vac 
7.Potential measurement inaccuracy EpmV+%+/- 3 mV  +/- 0.5% 
8.Reference electrode input circuit overvoltage limitation EoV+/- 20VImax=2A@ t=10/1000us pulse
9.Series input resistance of overvoltage limitation circuitOhm10k 
10.Voltage measurement range U_a measured at output terminals Au-KuV0+Us – 4 
11.Voltage measurement inaccuracy U_aV+%+/- 0.2V +/-2% 
12.Overvoltage limitation of the reference electrode input circuit EoV+/- 33VImax=5.5A@ t=10/1000us pulse
13.Series output resistance of the anode circuitOhm0.1 
14.Current consumption of the station without OK installation circuits:- for a lit display- for a non-lit display- for a lit display- for a non-lit display   mAmA 6958 7362 @ Us = 24 Vdc
 mAmA 4938 5746 @ Us = 48 Vdc
15.Interval of writes to non-volatile memorymin.120 000 
16.Maximum number of samples written to non-volatile memoryresults196 000> 22 years for 1/60 min recording.
17.Programmable sampling time interval to memory in “oscilloscope” modet0.1ms1000msts
Maximum number of samples saved in “oscilloscope” mode 3000 
Maximum waveform recording time in oscilloscope modet1,000 ms
3,000,000 ms
For ts= 0.1 ms
For ts= 1000 ms
18.Fuse type: 5×20 T250VStation protection in the housingAWTAT 1.6 A/250VModels: 24-1000 and 48-1000;
AWTAT 3.15 A/250VModel 24-2000; Model 48-2000
AWTAT 5 A/250VModel 24-4000;

 

  1. PARAMETERS GENERAL
No.General:UnitValue
1.dimensions width x height x depthmm105 x 90 x 65
2.weightkg.approx. 0.42
3.maximum ambient temperature at full load power°C-20 to +45
4.maximum ambient relative humidity%95

 