SOLLICH 1606 CPS
Cathodic Protection Station

Cathodic Protection Station with increased output current.

Controlled by a microprocessor.

Programming the current value with buttons:
SET + UP or SET + DOWN.

U: 12 – 24 Vdc

RS 485 communication interface.

Energy efficiency up to 96%.

Documentation

and technical data

Description

The SOLLICH 1606 CATHODIC PROTECTION MICROSTATION  is a device intended for the cathodic protection of metal and reinforced concrete structures. This protection consists in providing the appropriate protection potential of the structure by forcing current in the anode system – a protected construction.

The cathodic protection station SOLLICH 1606 CATHODIC PROTECTION MICROSTATION is a programmable current source device and works in a two-electrode system – without a reference electrode, or a three-electrode system in combination with a reference electrode.

The device enables programming of the cathodic protection current Ip and maintains this value during operation.

The device measures the value of the switching potential Eon of the structure protection against the reference electrode Eo (measuring), cathodic protection current Ip and anode-cathode Ua voltage.

Device functions

  • Operation in galvanostatic mode – current excitation and potentiostatic mode – potential excitation,
  • Multiple operating modes and configuration functions for a wide range of applications,
  • Programmable current and potential setting,
  • Automatic precision measurements,
  • LCD alphanumeric display with backlight, information on the current operating status of the station,
  • Cyclic recording of measurements performed in the non-volatile station memory,
  • Signaling “Control of the potential range” with colors: green, red and yellow-orange,
  • Programming the scope of potential control,
  • The ability to enable / disable signaling “Potential range control”,
  • Generating alarm signals,
  • High energy efficiency,
  • ZRemote reading and adjustment of operating parameters, communication with external devices, support for the ModBus protocol,
  • Easy installation on a DIN rail, simple commissioning, easy operation,
  • Software for reading results from station memory and for setting protection parameters.

Technical data

Parameter:Units.Min.Max.
Output current Ip

Model 24-1000

Model 24-2000

Model 24-4000

mA

mA

mA

40

80

160

1000

2000

4000

Ip measurement inaccuracy

Model 24-1000

Model 24-2000

Model 24-4000

mA+%

mA+%

mA+%

 

+/- 10mA  +/- 2%

+/- 20mA  +/- 2%

+/- 40mA  +/- 2%

     

*) Programmable potential Ep = Eon.

**) Range of potential measurement Eon: (0/-3,0)[V].

***) Inaccuracy in the measurement of potential Eon:  +/- 10mV  +/- 2%.

****) Communication port RS 485 MODBUS.

*****) Memory for 10 years of recording.

Additional products

offering additional options

Masz więcej pytań?